Digibell Vandal Resistant System Guía de instalación Pagina 35

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 56
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 34
Digibell Vandal Resistant System
PD-169 Issue 3B Installation Guide Page 35 of 56
Example:
Isolator
(DBA-8Z)
Address
Range
SW6
Position
SW7 setting
Comment
1 103-107
1
(1
-
8)
2, 4 ON
(+102)
Choose 1-8 then add offset +102
2 108-112
2
(5
-
12)
1, 2, 4 ON
(+103)
Choose 5-12 then add offset +103
3 114-122
4
(13
-
20)
1, 4 ON
(+101)
Choose 13-20 then add offset +101
In the example above, Isolators 1 and 2 use only five phone connections each; the last three
outputs of Isolator 1 would be 108, 109, 110 which, although unused, conflict with the first 3
addresses of Isolator 2; similarly with Isolators 2 and 3. Solution: disable the last three
outputs of each isolator.
Disabling phone outputs: (Note 1st and 2nd phones cannot be disabled)
SW7 setting
Phone
1
Phone
2
Phone
3
Phone
4
Phone
5
Phone
6
Phone
7
Phone
8
[1234567i]
Seven Phones Used disabled
[123456ui]
Six Phones Used disabled disabled
[12345yui]
Five Phones Used
disabled disabled disabled
[1234tyui]
Four Phones Used
disabled disabled disabled disabled
[123rtyui]
Three Phones Used disabled disabled disabled disabled disabled
[12ertyui]
Two Phones Used disabled disabled disabled disabled disabled disabled
1. On the DBA-8Z isolator set SW7 from the table above:
2. Set SW6 to 0
3. Press the Test button briefly and confirm the Status LED flashes (2 sec. duration)
4. If required confirm the output status by following the directions below.
5. Return SW6 & SW7 to the correct address setting for the Isolator
Confirming status of Isolator Outputs
To confirm which phone outputs have been disabled, set SW6 to 0 and SW7 to ‘All OFF’ and
press the Test button; each output will have its status LED flash once in turn except those
outputs which have been disabled. Note it may be necessary to press the Test button a
second time on a live system to ensure that the PCB has been reset.