Digibell Vandal Resistant System
PD-169 Issue 3B Installation Guide Page 39 of 56
Ringer volume
This model has 2 ring levels ‘Low’, ‘Medium’ and ‘High’, the default is ‘High’. It the ringer is
too loud move the jumper marked ‘Ring Volume’ on the PCB to the ‘Medium’ or ‘Low’
position.
Ringer mute time
The phone can be set so that after pressing the mute button the ringer is disabled for a set
time and then automatically re-enables itself. This time is adjustable between 2 minutes and
10 hours. It can typically be used to silence the ringer over night. The default setting disables
the ringer until the button is pressed again (not cancelling automatically). Refer to the table
above or the label inside the phone.
The settings for ‘Ring type’, ‘Door Monitor’ and ‘Unlock time’ should be left on the defaults
(DIP switch 1-4 should be all OFF) as they are not used on the Digibell system.
Phone connections
I Call (12V to ring)
R Microphone speech
O Common for ring, speech and lock button (0V)
T Speaker
Z Lock button (Z shorts to O when the lock button is pressed)
V 12V Phone supply (BS-LX only)
L Door Monitor (connecting L to 0V brings green LED on, BS-LX
only)