Special addressing
On the rare occasion when flat numbers skip every other number, e.g. 1,3,5,7 etc or 2,4,6,8
etc the jumper on the ‘PROG’ 6 pin header can be moved to pins 3 and 4.
If flat numbers are required in the range 3200 to 6400 the jumper on the ‘PROG’ 6 pin header
can be moved to pins 5 and 6. This simple adds an offset of +3200 to any address set on
SW6 and SW7.
Alphanumeric Flat Numbers
Flat numbers requiring alphabetic characters ( eg A1-A8, B101-B108, 101C-108C) cannot be
programmed on the Isolators and must be programmed into each individual telephone.
Please contact Bell System for instructions in this case.
Phone ring test
This can be used to ring a phone on one of the 8 outputs and see off hook and lock button
operation. It does not test the speech.
1. Press the Test button twice to ensure the system is in idle
2. Set SW7 to test the appropriate phone (only one phone at a time):
1 ON 1
st
Phone
2 ON 2
nd
Phone
3 ON 3
rd
Phone
4 ON 4
th
Phone
5 ON 5
th
Phone
6 ON 6
th
Phone
7 ON 7
th
Phone
8 ON 8
th
Phone
3. Press Test to ring the phone.
4. If the phone is taken off-hook the speech light will come on and go back off when the
phone is replaced.
5. If the lock button is pressed the status LED will come on for 3 seconds, if using the
BS-LX phone the green LED on the phone will also come on for 3 seconds.
6. Press the test button at any time to cancel.
7. Restore SW7 to the required address setting