Digibell Vandal Resistant System
PD-169 Issue 3B Installation Guide Page 53 of 56
Diagram 13 – Combined System Connections
Connecting a Bell PAX1 Proximity Reader
Connect the lock release as per this manual. Leave the Proximity Reader set to fail secure,
the BSD-DIG controller sets the lock type.
Note 1. A normally open exit button can still be wired to the BSD-DIG controller in addition
to the proximity wiring.
Opening/Triggering a Gate or Locks on a Third Party System
Leave the BSD-DIG controller set to Fail secure.
Generally when connecting to a third party system the lock release should be connected as
recommended by the other manufacturer; the NO and COM connections from the 89 relay,
as shown above, should be connected to a trigger input on the third party system, often
marked RTE (request to exit). For further advice please contact your distributor.